Coriolis Mass Flow Meter

MODEL: CMF250-20

CMF250-20 Series Coriolis mass flow meter is designed according to micro motion and Coriolis principle. It is a leading precision flow and density measurement solution offering .
The Coriolis flow meter worked on the Coriolis effect and was named. Coriolis flow meters are considered to be true mass flow meters because they tend to measure mass flow directly, while other flow meter techniques measure volume flow.

Contact us

Email

info@cbroindia.com sales@cbroindia.com

Sales Support

+917021306718

Technical Support

+918591988100

Advantages

Coriolis Type Flow Meter Advantages
It has high measurement accuracy, standard accuracy 0.2%; And the measurement is not affected by the physical properties of the medium.
Coriolis type flow meter provide a direct mass flow measurement without the addition of external measurement instruments. While the volumetric flow rate of the fluid will vary with changes in density, the mass flow rate of fluid is independent changes.
Flow meters are operated by flow characteristics such as turbulence and flow distribution. Therefore, upstream and downstream direct pipe operating  flow regulation requirements are not required.

Application

● Petroleum, such as crude oil, coal slurry, lubricant and other fuels.

● High viscosity materials, such as asphalt, heavy oil and grease;

● Suspended and solid particulate matter materials, such as cement slurry and lime slurry;

● Easy-to-solidified materials, such as asphalt

● Accurate measurement of medium- and high-pressure gases, such as CNG oil and gas

● Micro-flow measurements, such as fine chemical and pharmaceutical industries;

Water Treatment

Food Industry

Pharmaceutical Industry

Metallurgical Industry

Public Drainage

Chemical Monitoring

Technical Data

Table 1: Coriolis Mass Flow Meter Parameters

Technical Specifications
Make
CBRO
Model
CMF250-20
Flow Accuracy
±0.2% Optional ±0.1%
Diameter
DN3~DN200mm
Flow repeatability
±0.1~0.2%
Density measuring
0.3~3.000g/cm3
Density accuracy
±0.002g/cm3
Temperature measuring range
-200~300℃ (Standard Model -50~200℃)
Temperature accuracy
+/-1℃
Output of current loop
4~20mA; Optional signal of flow rate/Density/Temperature
Output of frequency/pulse
0~10000HZ; Flow signal (Open collector)
Communication
RS485, MODBUS protocol
Power supply of transmitter
18~36VDC power≤7W or 85~265VDC power 10W
Protection class
IP67
Material
Measuring tube SS316L housing:SS304
Pressure rating
4.0Mpa (Standard pressure)
Explosion-proof
Exd(ia) IIC T6Gb
Enviroment Specifications
Ambient temperature
-20~-60℃
Enviroment humidity
≤90%RH

Table 3: Coriolis Mass Flow Meter Flow Range

Specification
DN (mm)
Flow range (kg/h)
Zero stability, kg/h
NW (kg)
GW (kg)
CMF250-20-003
3
0~96~120
0.018
0.012
0.012
8
19
CMF250-20-006
6
0~540~660
0.099
0.066
0.066
12
22
CMF250-20-008
8
0~960~1200
0.18
0.12
0.12
12
23
CMF250-20-010
10
0~1500~1800
0.27
0.18
0.18
11
24
CMF250-20-015
15
0~3000~4200
0.63
0.42
0.42
12
25
CMF250-20-020
20
0~6000~7800
1.17
0.78
0.78
20
34
CMF250-20-025
25
0~10200~13500
2.025
1.35
1.35
21
35
CMF250-20-032
32
0~18000~24000
3.6
2.4
2.4
27
45
CMF250-20-040
40
0~30000~36000
5.4
3.6
3.6
35
55
CMF250-20-050
50
0~48000~60000
9
6
6
40
60
CMF250-20-080
80
0~120000~160000
24
16
16
90
150
CMF250-20-100
100
0~222000~270000
40.5
27
27
170
245
CMF250-20-150
150
0~480000~600000
90
60
60
255
350

Table 2: Coriolis Mass Flow Meter Dimension

Model
A
B
C
D
E
NW(only sensor)
mm
mm
mm
mm
mm
kg
CMF250-20-020
250
448
500
89
233
17
CMF250-20-025
550
500
445
108
238
17.5
CMF250-20-032
550
500
445
108
240
24
CMF250-20-040
600
760
500
140
245
32
CMF250-20-050
600
760
500
140
253
36
CMF250-20-080
850
1050
780
220
315
87.5
CMF250-20-100
1050
1085
840
295
358
165
CMF250-20-150
1200
1200
950
320
340
252
CMF250-20-200
1200
1193
1000
400
358
350
Model
A
B
C
D
E
Nw
mm
mm
mm
mm
mm
kg
CMF250-20-003
178
176
250
54
244
48
CMF250-20-006
232
263
360
70.5
287
8.1
CMF250-20-00B
232
275
395
70.5
290
82
CMF250-20-010
95
283
370
70.5
242
65
CMF250-20-015
95
302
405
70.5
242
65

Table 4: Coriolis Mass Flow Meter Mode Selection

CMF250-20
XXX
X
X
X
X
X
X
X
X
X
Caliber (mm)
DN3mm-DN200 mm
Nominal Pressure
0.6Mpa
1
1.0Mpa
2
1.6Mpa
3
2.5Mpa
4
2.5Mpa
5
Others
6
Connection
Flange
1
Wafer
2
Tri-clamp(Sanitary)
3
Thread
4
Insertion
5
Others
6
Medium
Liquid
1
Common Gas
2
Saturated Steam
3
Superheated Steam
4
Others
5
Special Mark
Normal
N
Standard Signal Output
M
Intrinscally safe Explosion-proof
B
On Site Display
X
High Temperature (350℃)
G
Temperature Compensation
W
Pressure Compensation
Y
Temperature&Pressure Compensation
Z
Structure Type
Compact/Integral
1
Remote
2
Power Supply
DC24V
D
3.6V Lithium Battery
E
Others
G
Output Signal
4-20mA
A
Pulse
B
4-20mA,HART
C
4-20mA,HART
D
4-20mA/Pulse,HART
D
Others
E
Flange Standard
DIN PN16
1
DIN PN25
2
DIN PN40
3
DIN PN40
A
ANSI 300#
B
ANSI 600#
C
JIS 10K
E
JIS 40K
F
Others
G

Installation

Coriolis Mass Flow Meter Installation
1. Basic Requirements on installation
(1)Flow direction should be in accordance with PHCMF sensor flow arrow. 
(2)Properly supporting is required for preventing tubes vibrating.
(3)If a strong pipeline vibration is inevitable, it is recommended to use a flexible tube to isolate the sensor from the pipe.
(4)Flanges should be kept parallel and their center points should be located on the same axis to avoid subsidiary force generation.
(5)Installation vertically, make the flow from the bottom up when measuring, meanwhile, the meter should not be installed on the top to prevent air getting trapped inside the tubes.
2.Installation Direction
In order to ensure the reliability of the measurement, the ways of installation should consider the following factors:
(1)The meter should be installed downward when measuring liquid flow (Figure 1), so that air cannot get trapped inside the tubes.
(2)The meter should be installed upward when measuring gas flow (Figure 2),  so that liquid cannot get trapped inside the tubes.
(3)The meter should be installed sideward when the medium is turbid liquid (Figure 3) to avoid particulate matter accumulated in the measuring tube. The flow direction of medium goes from the bottom up through the sensor.
 

SEND YOUR INQUIRY

Exported to more than 150 countries around the globe, 10000 sets/month production capacity!

OUR GLOBAL PRESENCE

Nature of business – MANUFACTURER , EXPORTER