Product Categories

Flange Ultrasonic Level Meter

MODEL: ULT252-2

Flange ultrasonic level meter  is based on the Time-of-Flight principle. A sensor emits ultrasonic pulses, the surface of the media reflects the signal and the sensor detects it again. The Time-of-Flight of the reflected ultrasonic signal is directly proportional to the distance traveled. With the known tank geometry the level can be calculated.

Contact us

Email

info@cbroindia.com sales@cbroindia.com

Sales Support

+917021306718

Technical Support

+918591988100

Advantages

Flange Ultrasonic Level Meter Advantages
Non-contact, maintenance-free measurement.
Measurement unaffected by media properties, like dc value or density.
Calibration without filling or discharging.
Self-cleaning effect due to vibrating sensor diaphragm.

Application

Flange ultrasonic level meter application
Flange Ultrasonic level meter with ultrasonic level sensors provides continuous, non-contact and maintenance-free level measurement of fluids, pastes, sludges and powdery to coarse bulk materials. The measurement is unaffected by dielectric constant, density or humidity and also unaffected by build-up due to the self-cleaning effect of the level sensors.

Storage Tank

Pool

Drains

Granary

Wells

Metering Box

Technical Data

Table 1: Flange Ultrasonic Level Meter Technical Parameters

Technical Specifications
Make
CBRO
Model
ULT252-2
Level Range
4,6,8,10,12,15,20,30m
Accuracy
0.5%-1.0%
Resolution
3mm or 0.1%
Display
LCD Display
Analog Output
Two Wires 4-20mA/250Ω Load
Power Supply
DC24V
Environmental Temperature
Transmitter -20~+60℃ , Sensor -20~+80℃
Communication
HART
Protection Class
Transmitter IP65(IP67 Optional),Sensor IP68
Probe Installation
Flange, Thread

Table 2: Flange Ultrasonic Level Meter Model Selection

Measure Range
4 4m 6 6m 8 8m 12 12m 20 20m 30 30m
License
P Standard Type(Non ex-proof) I Intrinsically safe (Exia IIC T6 Ga)
Energy Transducer Material/Process Temperature/Protection Grade
A ABS/(-40-75)℃/IP67 B PVC/(-40-75)℃/IP67 C PTFE/(-40-75)℃/IP67
Process Connection/Material
G Thread D Flange /PP
Electronic Unit
2 4~20mA/24V DC Two Wire 3 4 20mA/24V DC /HART Two Wire 4 4-20mA/24VDC/RS485 Modbus Four Wire 5 4-20mA/24VDC/Alarm Output Four Wire
Shell / Protection Grade
L Aluminum / IP67
Cable Entry
N 1/2 NPT
Programmer/Display
1 With Display

Installation

Flange Ultrasonic Level Meter Installation
1:Keep Ultrasonic Level Transmitter perpendicular to liquid.
2:The transducer should not be mounted too close to the tank wall, the bracket can cause strong false echoes
3:Mount the transducer away from the inlet to avoid false echoes.
4:The transducer should not be mounted too close to the tank wall, the build-up on the tank wall cause false echoes.
5:As is illustrated by the figure on the below, the transducer should be mounted on the top of guide tube to prevent the false echoes from turbulence and foam. The guide tube should come with a vent hole at top of the tube to allow the liquid vapor go out of the tube.
6:When you mount the transducer on the solid tank, the transducer must point to the tank outlet.