Contact us

Email

info@cbroindia.com sales@cbroindia.com

Sales Support

+917021306718

Technical Support

+918591988100

Advantages

Accuracy better than ±1.0% High reliability, high performance, low price
Bi-directional flow measurement No moving parts, no wear, no pressure loss,Maintenance-free  Measuring conductivity liquid and Non-conductivity liquid Display instantaneous flow,Total flow,Heat,Positive flow,Negative flow High precision machined pipe sections, the sensor is installed before leaving the factory to ensure high measurement accuracy

Food industry

Oil & Gas industry

Chemical industry

Water treatment industry

Trade settlement

Power industry

Technical Data

Table 1 : Integral Display Flange Ultrasonic Flow Meter Main Performances Parameters

TECHNICAL SPECIFICATIONS
Make
CBRO
Model
CUF700
Size
DN15~DN6000
Accuracy
Better than ±1.0%
Velocity range
0~±10m/s
Liquid temperature
0~160℃
Liquid Type
Water, sea water, waste water, alcohol, beer, various kinds of oil etc which can conduct ultrasound single uniform liquid
Pipe material
Steel, stainless steel, cast iron, copper, PVC, aluminum, FRP etc, all kinds Of dense pipeline, can be liner inside
Output signal
1 channel 4-20mA output, inpedence 0-1K ; 1 channel OCT pulse output, pulse width 6-1000ms, (default is 200ms); 1 channel relay output
Input Signal
4-20mA input Connect with three wire PT100, can achieve heat measurement
Communication
RS485 MODBUS RTU
Power supply
DC8-36V or AC85-264V
Protection
IP65
Power Consumption
1.5W

Table 2 : Water temperature and sound speed table

Temperature(℃ )
Sound speed (m/s)
Temperature(℃)
Sound speed (m/s)
0
1403
50
1541
5
1427
55
1546.5
10
1447
60
1552
15
1464
65
1553.5
20
1481
70
1555
25
1494
75
1555
30
1507
80
1555
35
1516.5
85
1552.5
40
1526
90
1550
45
1533.5
95
1547
100
1543

Table 3 : Ultrasonic flow meter model selection

Size
DN15~DN6000
15~6000
X
X
X
X
X
Body Material
Carbon steel
C
SS304
S0
SS316
S1
Pressure Rate
0.6 Mpa
P1
1.0 MPa
P2
1.6 MPa
P3
2.5 MPa
P4
Other special
P5
Output
4-20mA,Pulse,OCT,RS485
O
Structure
Integral
I
Remote
R
Connection
Thread
T
Flange
F

Installation

Integral Display Flange Ultrasonic Flow Meter Installation Requirement
Generally, the following principles should be followed:

To select a pipe section filled with fluid, such as a vertical part of the pipeline or a horizontal pipe section filled with fluid.

The measuring point should be 10 times the diameter from the upstream and the straight pipe section within 5 times the diameter from the downstream, and the distance from the valve outlet should be as far as possible.

Ensure the temperature at the measuring point is within the working range. 

Fully consider the fouling condition of the inner wall of the pipe, and try to select a non-scaling pipe section for measurement. When it cannot be satisfied, fouling should be considered as a lining for better measurement accuracy. 

Select pipe sections with uniform and dense pipes that are easy for ultrasonic transmission.

Please refer to the two examples on the right for the selection of measuring points. 

Other Products in ' Ultrasonic Flow Meter' category

SEND YOUR INQUIRY

Exported to more than 150 countries around the globe, 10000 sets/month production capacity!