Product Categories

Battery Powered Electromagnetic Flow Meter

MODEL: POWERMAG2500

Battery-powered magnetic flow meter can be used in remote area where don’t have power grid . It is widely used for all conductive liquids in every industry, such as water, acid, alkali, milk, slurry etc. Since founded in 2005, CBRO has been focused in magnetic flow meter manufacturing for more than 15 years. More than 600 thousand mag meters had been provided to clients all over the world for different work conditions.

Contact us

Email

info@cbroindia.com sales@cbroindia.com

Sales Support

+917021306718

Technical Support

+918591988100

Advantages

Battery Powered Electromagnetic Flow Meter Advantages and Disadvantages
1.It has a long life span, standard battery can work for 3-6 years, determined by the excitation current
2.Dual power supply: it’s equipped with external power supply interface, which
can be powered by external 12-24vdc power supply, enabling users to have a variety of power options;
3. Multiple network interfaces: W803 has GPRS, RS485, HART and other network communication for users;
4.Multiple work mode: W803E has ‘Flow Only’ mode, ‘Flow + Pressure’ mode, ‘Flow + Temperature’ mode for users. 

Application

Electromagnetic flow meter is widely used in water treatment, food industry, pharmaceutical, petrochemical, paper mill, chemical monitoring etc. 
In the metallurgical industry, it is often used to control the flow of cooling water for continuous steel casting, continuous steel rolling, and steel-making electric furnaces; In the field of water supply and drainage in public utilities, electromagnetic flow meters are often used for the transfer measurement of finished product water and raw water in water plants; In the pulp process of the paper industry, electromagnetic flow meters are involved in the measurement of the flow of grinding pulp, water, acid, and alkali;  In the coal industry, measuring coal washing and pipeline hydraulic conveying coal slurry.
For food and beverage industries, it is used for beer and beverage filling measurement.
For chemical and petrochemical industries, it is used to measure corrosive liquids, such as acids and alkalis etc.

Water Treatment

Food Industry

Pharmaceutical Industry

Petrochemical

Paper Industry

Chemical Monitoring

Metallurgical Industry

Public Drainage

Coal Industry

Technical Data

Table 1: Battery Powered Electromagnetic Flow Meter Main Performances Parameters

Technical Specifications
Make
CBRO
Model
POWERMAG2500
SIZE
DN3-DN3000MM
Nominal Pressure
0.6-1.6Mpa(2.5Mpa/4.0Mpa/6.4Mpa...Max 42Mpa)
Accuracy
+/-0.5%(Standard) +/-0.3% or +/-0.2%(Optional)
Liner
PTFE, Neoprene, Hard Rubber, EPDM, FEP, Polyurethane, PFA
Electrode
SUS316L, Hastelloy B, Hastelloy C Titanium, Tantalum, Platinium-iridium
Structure Type
Integral type, remote type, submersible type, ex-proof type
Medium Temperature
-20~+60 degC(Integral type)
Remote type(Neoprene,Hard Rubber,Polyurethane,EPDM) -10~+80degC Remote type(PTFE/PFA/FEP) -10~+160degC
Ambient Temperature
-20~+60deg C
Ambient Humidity
5-100%RH(relative humidity)
Measuring Range
Max 15m/s
Conductivity
>5us/cm
Protection Class
IP65(Standard); IP68(Optional for remote type)
Process Connection
Flange (Standard), Wafer, Thread, Tri-clamp etc (Optional)
Output Signal
4-20mA/Pulse
Communication
RS485(Standard), HART(Optional),GPRS/GSM (Optional)
Power Supply
AC220V (can be used for AC85-250V) DC24V (can be used for DC20-36V) DC12V (optional), Battery Powered 3.6V (optional)
Power Consumption
<20W
Alarm
Upper Limit Alarm / Lower Limit Alarm
Self-diagnosis
Empty Pipe Alarm, Exciting Alarm
Explosion Proof
ATEX

Table 2: Battery Powered Electromagnetic Flow Meter Electrode Material Selection

Technical Specifications
Make
CBRO
Model
POWERMAG2500
ELECTRODE MATERIAL
APPLICATIONS & PROPERTIES
SUS316L
Applicable to industrial/municipal water, wastewater and low corrosive mediums. Widely used in petroleum, chemical industries.
Hastelloy B
Strong resistance to hydrochloric acids below the boiling point. Resist against oxidable acids, alkali and non-oxidable salts. For instance, vitriol, phosphate, hydrofluoric acids, and organic acids.
Hastelloy C
Exceptional resistance to strong solutions of oxidizing salts and acids. For example, Fe+++, Cu++, Nitric acids, mixed acids
Titanium
Titanium can withstand corrosive mediums such as seawater, chloride salt solutions, hypochlorite salts, oxidable acids(including fuming nitric acids), organic acids, and alkali. Not resistant to high purity reducing acids such as sulphuric acids, hydrochloric acids.
Tantalum
Highly resistant to corrosive mediums. Applicable to all chemical mediums except Hydrofluoric Acids, Oleum and Alkali.
Platinum-iridium
Applicable to all chemical mediums except for Ammonium salts and Fortis

Table 3: Battery Powered Electromagnetic Flow Meter Flow Range

Size
Flow Range & Velocity Table
(mm)
0.1m/s
0.2m/s
0.5m/s
1m/s
4m/s
10m/s
12m/s
15m/s
3
0.003
0.005
0.013
0.025
0.102
0.254
0.305
0.382
6
0.01
0.02
0.051
0.102
0.407
1.017
1.221
1.526
10
0.028
0.057
0.141
0.283
1.13
2.826
3.391
4.239
15
0.064
0.127
0.318
0.636
2.543
6.359
7.63
9.538
20
0.113
0.226
0.565
1.13
4.522
11.304
13.56
16.956
25
0.177
0.353
0.883
1.766
7.065
17.663
21.2
26.494
32
0.289
0.579
1.447
2.894
11.575
28.938
34.73
43.407
40
0.452
0.904
2.261
4.522
18.086
45.216
54.26
67.824
50
0.707
1.413
3.533
7.065
28.26
70.65
84.78
105.98
65
1.19
2.39
5.97
11.94
47.76
119.4
143.3
179.1
80
1.81
3.62
9.04
18.09
72.35
180.86
217
271.3
100
2.83
5.65
14.13
28.26
113.04
282.6
339.1
423.9
125
4.42
8.83
22.08
44.16
176.63
441.56
529.9
662.34
150
6.36
12.72
31.79
63.59
254.34
635.85
763
953.78
200
11.3
22.61
56.52
113.04
452.16
1130.4
1356
1696
250
17.66
35.33
88.31
176.53
706.5
1766.25
2120
2649
300
25.43
50.87
127.2
254.34
1017
2543.4
3052
3815
350
34.62
69.24
173.1
346.19
1385
3461.85
4154
5193
400
45
90
226.1
452
1809
4522
5426
6782
450
57
114
286.1
572
2289
5723
6867
8584
500
71
141
353.3
707
2826
7065
8478
10598
600
102
203
508.7
1017
4069
10174
12208
15260
700
138
277
692.4
1385
5539
13847
16617
20771
800
181
362
904.3
1809
7235
18086
21704
27130
900
229
458
1145
2289
9156
22891
27469
34336
1000
283
565
1413
2826
11304
28260
33912
42390
1200
407
814
2035
4069
16278
40694
48833
61042
1400
554
1108
2769
5539
22156
55390
66468
83084
1600
723
1447
3617
7235
28938
72346
86815
108518
1800
916
1831
4578
9156
36625
91562
109875
137344
2000
1130
2261
5652
11304
45216
113040
135648
169560
2200
1368
2736
6839
13678
54711
136778
164134
205168
2400
1628
3256
8139
16278
65111
162778
195333
244166
2600
1910
3821
9552
19104
76415
191038
229245
286556
2800
2216
4431
11078
22156
88623
221558
265870
332338
3000
2543
5087
12717
25434
101736
254340
305208
381510
Remark:Suggest flow velocity range 0.5m/s - 15m/s

Table 4: Battery Powered Electromagnetic Flow Meter Selection Guide

QTLD
xxx
x
x
x
x
x
x
x
x
Caliber
DN3mm-DN3000mm
Nominal Pressure
0.6Mpa
1
1.0Mpa
2
1.6Mpa
3
4.0Mpa
4
Other
5
Nominal Pressure
Flange connection
1
Clamp connection
2
Sanitary connection
3
Liner Material
PTFE
1
PFA
2
Neoprenen
3
Polyurethane
4
Ceramic
5
Electrode Material
316L
1
Hastelloy B
2
Hastelloy C
3
Titanium
4
Platinum-iridium
5
Tantalum
6
Stainless steel covered with tungsten carbide
7
Structure Type
Integral type
1

Installation

Battery Powered Electromagnetic Flow Meter Installation Requirement
In order to obtain a stable and accurate flow measurement, it is very important that the flow meter is installed correctly in the pipe system.
Do not install the meter near equipment that produces electrical interference such as electric motors, transformers, variable frequency, power cables etc.
Avoid locations with pipe vibrations for example pumps.
Do not install the meter close to pipeline valves, fittings or impediments which can cause flow disturbances.
Place the meter where there is enough access for installation and maintenance tasks.


lnstall at the lowest point and vertical upward direction
Don’t install at the highest point or vertical downward diection

When drop is more than 5m, install exhaust
valve at the downstream

lnstall at the lowest point when used in open drain pipe

Need 10D of upstream and 5D of downstream

Dont’ install it at the entrance of pump, install it at the exit of pump

lnstall at the rising direction

Other Products in ' Electromagnetic Flow Meter' category

SEND YOUR INQUIRY

Exported to more than 150 countries around the globe, 10000 sets/month production capacity!