Product Categories

Tri-clamp Electromagnetic Flow Meter

MODEL: DIGIMAG250 Series

Tri-clamp electromagnetic flow meter is a kind of volume flow meter. Tri-clamp electromagnetic flow meter is made of stainless steel, which can be easily disassembled and cleaned quickly, so it is not easily polluted during use, and can effectively prevent the accumulation of measuring fluid residues in the measuring tube. 
Wafer electromagnetic flow meter working: The product is based on Faraday’s law of electromagnetic induction, used to measure the conductance greater than 20 μS/cm volume of conductive liquid flow. In addition to measuring the general volume of conductive liquid flow, but also can be used to measure strong acid, alkali and other strong corrosive liquids and mud, pulp, etc.

Contact us

Email

info@cbroindia.com sales@cbroindia.com

Sales Support

+917021306718

Technical Support

+918591988100

Advantages

Tri-clamp Electromagnetic Flow Meter Advantages and Disadvantages:
Tri-clamp electromagnetic flow meter is easy to be installed and dismantled. It adopts Harmless food grade stainless steel as raw material, so it can touch with food directly.
Stainless steel material has long service life, and SS316 is a kind of anti-corrosive stainless steel, so it can be used to measure most of drinks. It has small size and light weight so it can save your freight fee.
It has multiple output signals for choose. It has current output and pulse output for connecting with PLC or other devices. And you can also read flow measurement by RS485/HART/Profibus.

Application

Tri-clamp electromagnetic flow meter is mainly used in drinking water, milk, ground water, beer, wine, jam, juice and other food & drink industries. It is also widely used in paper pulp, gypsum slurry because it can be cleaned easily.
It adopts harmless stainless steel material so it can measure food directly. And it can withstand high temperature steam disinfection.
Local display type can withstand -20-60 deg C temperature, remote display can withstand -20-120 deg C.

Water Treatment

Food Industry

Pharmaceutical Industry

Petrochemical

Paper Industry

Chemical Monitoring

Metallurgical Industry

Public Drainage

Coal Industry

Technical Data

Table 1: Tri-clamp Electromagnetic Flow Meter Parameters

Technical Specifications
Make
CBRO
Model
DIGIMAG250 Series
SIZE
DN15MM-DN200MM
Nominal Pressure
1.6Mpa
Accuracy
±0.5%(Standard) ±0.3% or ±0.2%(Optional)
Liner
FEP, PFA
Electrode
SUS316L, Hastelloy B, Hastelloy C, Titanium, Tantalum, Platinum-iridium
Structure Type
Integral type, remote type, submersible type, ex-proof type
Medium Temperature
-20~+60degC(Integral type)
Remote type(PFA/FEP) -10~+160degC
Ambient Temperature
Ambient Humidity
5~90%RH(relative humidity)
Measuring Range
Max 15m/s
Conductivity
>5us/cm
Protection Class
IP65(Standard); IP68(Optional for remote type)
Output Signal
4-20mA pulse frequency relay
Communication
MODBUS RTU RS485, HART(Optional), GPRS/GSM(Optional)
Power Supply
AC220V(Can be used for AC85-250V) DC24V(Can be used for DC20-36V) DC12V(Optional),Battery Powered 3.6V(Optional)
Power Consumption
<20W
Explosion Proof
ATEX Exdll T6Gb

Table 2: Tri-clamp Electromagnetic Flow Meter Electrode Material Selection

Technical Specifications
Make
CBRO
Model
DIGIMAG250 Series
SUS316L
Applicable in water, sewage and low corrosive mediums. Widely used in industries of petrol, chemistry, carbamide,etc
Hastelloy B
Having strong resistance to hydrochloric acid of any consistance which is below bioling piont. Resistable against vitriol, phosphate, hydrofluoricacid, organic acid etc which are oxidable acid, alkali and non-oxidable salt.
Hastelloy C
Be resistant to oxidable acid such as nitric acid, mixed acid as well as oxidable salt such as Fe+++, Cu++and sea water.
Titanium
Applicable in seawater, and kinds of chloride, hypochlorite salt, oxidable acid (including fuming nitric acid), organic acid, alkali etc. Not resistant to a pure reducing acid(such as sulphuric acid, hydrochloric acid corrosion. But if acid contains antioxidant(such as Fe+++, Cu++) is greatly reduce corrosion.
Tantalum
Having strong resistance to corrosive mediums that is similar with glass. Almost is applicable to all chemical mediums. Except for hydrofluoric acid,oleum and alkali.
Platinum-iridium
Almost be applicable in all chemical mediums except for ammonium salt.

Table 3: Tri-clamp Electromagnetic Flow Meter Sizing Chart

Diameter
φA(mm)
φB(mm)
φC(mm)
φD(mm)
φE(mm)
H(mm)
L(mm)
DN15
50.5
43.5
16
76
2.85
303
200
DN20
50.5
43.5
19
83
2.85
310
200
DN25
50.5
43.5
24
83
2.85
310
200
DN32
50.5
43.5
31
94
2.85
321
200
DN40
50.5
43.5
35
94
2.85
321
200
DN50
64
56.5
45
108
2.85
335
200
DN65
77.5
70.5
59
115
2.85
342
250
DN80
91
83.5
72
135
2.85
362
250
DN100
119
110
98
159
2.85
386
250
DN125
145
136
129
183
3.6
410
300
DN150
183
174
150
219
3.6
446
300
DN200
233.5
225
199
261
3.6
488
350

Table 4: Tri-clamp Electromagnetic Flow Meter Sizing Chart Flow Range ( Unit: m³/h )

Size
Flow Range & Velocity Table
(mm)
0.1m/s
0.2m/s
0.5m/s
1m/s
4m/s
10m/s
12m/s
12m/s
15
0.064
0.127
0.318
0.636
2.543
6.359
7.630
9.538
20
0.113
0.226
0.565
1.130
4.522
11.304
13.56
16.956
25
0.177
0.353
0.883
1.766
7.065
17.663
21.2
26.494
32
0.289
0.579
1.447
2.894
11.575
28.938
34.73
43.407
40
0.452
0.904
2.261
4.522
18.086
45.216
54.26
67.824
50
0.707
1.413
3.533
7.065
28.260
70.650
84.78
105.98
65
1.19
2.39
5.97
11.94
47.76
119.40
143.3
179.10
80
1.81
3.62
9.04
18.09
72.35
180.86
217.0
271.30
100
2.83
5.65
14.13
28.26
113.04
282.60
339.1
423.90
125
4.42
8.83
22.08
44.16
176.63
441.56
529.9
662.34
150
6.36
12.72
31.79
63.59
254.34
635.85
763.0
953.78
200
11.3
22.61
56.52
113.04
452.16
1130.40
1356
1696

Table 5: Tri-clamp Electromagnetic Flow Meter Model Selection

QTLD
XXX
X
X
X
X
X
X
X
X
Caliber
DN15mm-DN200mm
1
Nominal Pressure
1.6Mpa
1
Connection mode
sanitary connection
1
Liner material
FEP
1
PFA
2
Electrode material
316L
1
Hastelloy B
2
Hastelloy C
3
Titanium
4
Platinum-iridium
5
Tantalum
6
Stainless steel covered with tungsten carbide
7
Electrode material
Integral type
1
Remote type
2
Remote type immerse
3
Integral type Ex-proof
4
Remote type Ex-proof
5
Power
220VAC
E
24VDC
G
output communication
Flow volume 4-20mADC/pulse
A
Flow volume 4-20mADC/RS232 communication
B
Flow volume 4-20mADC/RS485 communication
C
Flow volume HART output/with communication
D
Converter figure
Square
A
Circular
B

Installation

Tri-clamp Electromagnetic Flow Meter Installation & Maintainance
Installation
1. The sensor is installed vertically (fluid flows from bottom to top). In this position, when the liquid is not flowing, solid matter will precipitate, and oily matter will not settle on the electrode if it floats up. 
If it is installed horizontally, the pipe must be filled with liquid to avoid air pockets from affecting the measurement accuracy.
2. The inner diameter of the pipe should be the same as the inner diameter of the flow meter to avoid throttling.
3. The installation environment should be far away from strong magnetic field equipment to prevent interference.
4. When using electric welding, the welding port must be far away from the sensor to prevent damage to the lining of the clamp-type electromagnetic flowmeter due to overheating of the sensor or flying in of welding slag.


lnstall at the lowest point and vertical upward direction
Don’t install at the highest point or vertical downward diection

When drop is more than 5m, install exhaust
valve at the downstream

lnstall at the lowest point when used in open drain pipe

Need 10D of upstream and 5D of downstream

Dont’ install it at the entrance of pump, install it at the exit of pump

lnstall at the rising direction

Maintenance
Routine maintenance: only need to make periodic visual inspections of the instrument, check the environment around the instrument, remove dust and dirt, ensure that no water and other substances enter, check whether the wiring is in good condition, and check whether there are newly installed strong electromagnetic field equipment or newly installed wires near the instrument Cross-instrument. If the measuring medium easily contaminates the electrode or deposits in the measuring tube wall, it should be cleaned and cleaned regularly.

Other Products in ' Electromagnetic Flow Meter' category

SEND YOUR INQUIRY

Exported to more than 150 countries around the globe, 10000 sets/month production capacity!