Product Categories

Partially Filled Pipe Electromagnetic Flow Meter

MODEL: DIGIMAG250 Series

Partially filled pipe electromagnetic flow meter is a kind of volume flow meter. It was specially designed for partially filled pipe. It can measure liquid volume from 10% level of the pipe to 100% level of the pipe. It’s accuracy can reach to 2.5%, very accurate for irrigation and waste water liquid measurement. It use remote LCD display so users can read the flow measurement easily. We also provide solar power supply solution for some remote areas where has no power supply.

Contact us

Email

info@cbroindia.com sales@cbroindia.com

Sales Support

+917021306718

Technical Support

+918591988100

Advantages

Partially filled pipe electromagnetic flow meter Advantages & Disadvantages

Partially filled pipe electromagnetic flow meter can measure partially filled pipe liquid flow, it is very popular in irrigation.
Its can use solar power supply, this type is very suitable for remote areas where has no industrial power supply.
It adopts safe and durable material, service life is longer than normal products. Normally, it can work at least 5-10 years or longer.
We use an accurate mini ultrasonic level meter for its liquid level measurement then the flow meter will record the liquid  use this parameter to measure liquid flow. 

Application

Partially filled pipe electromagnetic flow meter can measure water, waste water, paper pulp, etc. We use rubber or polyurethane liner on it, so it can measure most of none corrosive liquid. It is mainly used in irrigation, water treatment, etc.
It withstand -20-60 deg C media temperature, and it was very durable and safe.

Water Treatment

Waste Water

Irrigation

Metallurgical Industry

Public Drainage

Coal Industry

Technical Data

Table 1: Partially Filled Pipe Electromagnetic Flow Meter Parameters

Technical Specifications
Make
CBRO
Model
DIGIMAG250 Series
MEASURING PIPE SIZE
DN200-DN3000
Connection
Flange
Liner Material
Neoprene/Polyurethane
Electrode Marerial
SS316, TI, TA, HB, HC
Structure Type
Remote Type
Accuracy
2.5%
Output Signal
Modbus RTU, TTL electrical level
Communication
RS232/RS485
Flow speed range
0.05-10m/s
Protection Class
Converter: IP65 Flow Sensor: IP65(standard), IP68(optional)

Table 2: Partially Filled Pipe Electromagnetic Flow Meter Size

Drawing ( DIN Flange )
Diameter (mm)
Nominal pressure
L(mm)
H
φA
φK
N-φh
DN200
0.6
400
494
320
280
8-φ18
DN250
0.6
450
561
375
335
12-φ18
DN300
0.6
500
623
440
395
12-φ22
DN350
0.6
550
671
490
445
12-φ22
DN400
0.6
600
708
540
495
16-φ22
DN450
0.6
600
778
595
550
16-φ22
DN500
0.6
600
828
645
600
20-φ22
DN600
0.6
600
934
705
705
20-φ22
DN700
0.6
700
1041
860
810
24-φ26
DN800
0.6
800
1149
975
920
24-φ30
DN900
0.6
900
1249
1075
1020
24-φ30
DN1000
0.6
1000
1359
1175
1120
28-φ30

Table 3: Partially Filled Pipe Electromagnetic Flow Meter Model Select

QTLD/F
xxx
x
x
x
x
x
x
x
x
x
Diameter (mm)
DN200-DN1000 three digit number
Nominal pressure
0.6Mpa
A
1.0Mpa
B
1.6Mpa
C
The connection method
The flange type
1
Liner
neoprene
A
Electrode materials
316L
A
Hastelloy B
B
Hastelloy C
C
titanium
D
tantalum
E
Stainless steel coated with tungsten carbide
F
Structure form
Remote Type
1
Remote Type Diving type
2
The power supply
220VAC 50Hz
E
24VDC
G
12V
F
Output/communication
Volume flow 4~20mADC/ pulse
A
Volume flow 4~20mADC/RS232C serial communication interface
B
Volume flow 4~20mADC/RS485C serial communication interface
C
Volume flow HART protocol output
D
Converter form
square
A
Special tag

Installation

Partially Filled Pipe Electromagnetic Flow Meter Installation and Maintainance

1.Installation Partially filled electromagnetic flow meter should be installed correctly to ensure good measurement. Normally we need leave 10D(10 times of diameter) straight pipe distance before partially filled pipe electromagnetic flow meter and 5D behind partially filled pipe electromagnetic flow meter. And try to avoid elbow/valve/pump or other device which will influent the flow speed. If the distance is not enough, then please install flow meter according to follow picture.
lnstall at the lowest point and vertical upward direction Don’t install at the highest point or vertical downward diection
When drop is more than 5m, install exhaust valve at the downstream
lnstall at the lowest point when used in open drain pipe
Need 10D of upstream and 5D of downstream
Dont’ install it at the entrance of pump, install it at the exit of pump
lnstall at the rising direction
2.Maintenance Routine maintenance: only need to make periodic visual inspections of the instrument, check the environment around the instrument, remove dust and dirt, ensure that no water and other substances enter, check whether the wiring is in good condition, and check whether there are newly installed strong electromagnetic field equipment or newly installed wires near the instrument Cross-instrument. If the measuring medium easily contaminates the electrode or deposits in the measuring tube wall, it should be cleaned and cleaned regularly. 3.Fault finding: if the meter is found to work abnormally after the flow meter has been put into operation or normal operation for a period of time, the external conditions of the flow meter should be checked first, such as whether the power supply is good, whether the pipeline is leaking or in a state of partial pipe, whether there is any in the pipeline Whether air bubbles, signal cables are damaged, and whether the output signal of the converter (that is, the input circuit of the subsequent instrument) is open. Remember to dismantle and repair the flow meter blindly. 4.Sensor inspection 5.Converter check

Other Products in ' Electromagnetic Flow Meter' category

SEND YOUR INQUIRY

Exported to more than 150 countries around the globe, 10000 sets/month production capacity!