Product Categories

Insertion Type Electromagnetic Flow Meter

MODEL: FLOWMAG1600

Insertion type electromagnetic flow meter is a type of electromagnetic flow meter has been used throughout industries for more than 50years.  Insertion type electromagnetic flow meter comprise an electromagnetic sensing probe in  ABS or Polypropylene mounted on the end of a support rod. CBRO is a company that design and manufacture flowmeters with more than 15 years of experience. One piece CBRO insertion type electromagnetic flow meter can be used for pipe sizes between DN100mm and DN3000mm. 

Contact us

Email

info@cbroindia.com sales@cbroindia.com

Sales Support

+917021306718

Technical Support

+918591988100

Advantages

Insertion Type Electromagnetic Flow Meter Advantages and Disadvantages
The main advantages of using electromagnetic flow meter is that it is with no moving parts, no pressure loss and require very less maintenance.
Insertion type electromagnetic flow meter provide more economical option for large pipelines flow measurement, while preserving the advantages of common type magnetic flow meter. It is totally independent from the pressure, temperature and mechanical vibrations, density, viscosity etc. No scheduled maintenance required. It can achieve hot-tapping online installation. It can only be used for size above DN100mm, for smaller sizes below DN100mm it is not available.

Application

Insertion type electromagnetic flow meter provide more economical option for large pipelines flow measurement, while preserving the advantages of common type magnetic flow meter. 
Reliable Measurement-CBRO insertion electromagnetic flow meter with simple structure and no moving parts. It is totally independent from the pressure, temperature and mechanical vibrations, density, viscosity etc.  No scheduled maintenance required. 
Easy Installation-CBRO insertion electromagnetic flow meter can achieve online installation (hot-tapping).
Submersible Available-CBRO insertion electromagnetic flow meter can make as remote type with IP68 protection grade and with submersible sensors for complicated conditions. 
Variable Outputs-CBRO insertion electromagnetic flow meter support 4-20mA,pulse,RS485, GPRS and profibus available. 

Water Treatment

Food Industry

Pharmaceutical Industry

Petrochemical

Paper Industry

Chemical Monitoring

Metallurgical Industry

Public Drainage

Coal Industry

Technical Data

Table 1 : Insertion Type Electromagnetic Flow Meter Main Performances Parameters

Technical Specifications
Make
CBRO
Model
FLOWMAG1600
SIZE
DN100MM-DN3000MM
Nominal Pressure
1.6Mpa
Accuracy
1.5%
Probe
ABS, Polyurethane
Electrode
SUS316L, Hastelloy B, Hastelloy C
Structure Type
Integral type, remote type
Medium Temperature
-20~+80degC
Ambient Temperature
-20~+60degC
Ambient Humidity
5~100%RH(Relative humidity)
Measuring Range
Max 15m/s
Conductivity
>5us/cm
Protection Class
IP65(Standard); IP68(Optional for remote type)
Process Connection
2'' Thread(Standard), 2'' Flange(Optional)
Output Signal
4-20mA/Pulse
Communication
RS485(Standard), HART(Optional), GPRS/GSM(Optional)
Power Supply
AC220V(Can be used for AC85-250V) DC24V(Can be used for DC20-36V) DC12V(Optional), Battery powered 3.6V(Optional)
Power Consumption
<20W
Alarm
Upper Limit Alarm / Lower Limit Alarm
Self-diagnosis
Empty Pipe Alarm, Exciting Alarm
Explosion Proof
ATEX

Table 2 : Insertion Type Magnetic Flow Meter Electrode Material Selection

Technical Specifications
Make
CBRO
Model
FLOWMAG1600
ELECTRODE MATERIAL
APPLICATIONS & PROPERTIES
SUS316L
Applicable to industrial/municipal water, wastewater and low corrosive mediums. Widely used in petroleum, chemical industries.
Hastelloy B
Strong resistance to hydrochloric acids below the boiling point. Resist against oxidable acids, alkali and non-oxidable salts. For instance, vitriol, phosphate, hydrofluoric acids, and organic acids.
Hastelloy C
Exceptional resistance to strong solutions of oxidizing salts and acids. For example, Fe+++, Cu++, Nitric acids, mixed acids

Table 3 : Insertion Type Magnetic Flow Meter Flow Range

Size
Flow Range & Velocity Table
(mm)
0.1m/s
0.2m/s
0.5m/s
1m/s
4m/s
10m/s
12m/s
15m/s
100
2.83
5.65
14.13
28.26
113.04
282.6
339.1
423.9
125
4.42
8.83
22.08
44.16
176.63
441.56
529.9
662.34
150
6.36
12.72
31.79
63.59
254.34
635.85
763
953.78
200
11.3
22.61
56.52
113.04
452.16
1130.4
1356
1696
250
17.66
35.33
88.31
176.53
706.5
1766.25
2120
2649
300
25.43
50.87
127.2
254.34
1017
2543.4
3052
3815
350
34.62
69.24
173.1
346.19
1385
3461.85
4154
5193
400
45
90
226.1
452
1809
4522
5426
6782
450
57
114
286.1
572
2289
5723
6867
8584
500
71
141
353.3
707
2826
7065
8478
10598
600
102
203
508.7
1017
4069
10174
12208
15260
700
138
277
692.4
1385
5539
13847
16617
20771
800
181
362
904.3
1809
7235
18086
21704
27130
900
229
458
1145
2289
9156
22891
27469
34336
1000
283
565
1413
2826
11304
28260
33912
42390
1200
407
814
2035
4069
16278
40694
48833
61042
1400
554
1108
2769
5539
22156
55390
66468
83084
1600
723
1447
3617
7235
28938
72346
86815
108518
1800
916
1831
4578
9156
36625
91562
109875
137344
2000
1130
2261
5652
11304
45216
113040
135648
169560
2200
1368
2736
6839
13678
54711
136778
164134
205168
2400
1628
3256
8139
16278
65111
162778
195333
244166
2600
1910
3821
9552
19104
76415
191038
229245
286556
2800
2216
4431
11078
22156
88623
221558
265870
332338
3000
2543
5087
12717
25434
101736
254340
305208
381510

Table 4 : Insertion Electromagnetic Flow Meter Selection

QTLD/C
xxx
x
x
x
x
x
x
x
x
x
Caliber
DN100mm-DN3000mm
Nominal Pressure
1.6Mpa
3
Other
6
Body Material
SS304
1
SS316
2
Body Material
SUS316L
1
Hastelloy B
2
Hastelloy C
3
Probe Material
ABS
1
Polypropylene
2
Connection
Thread ball valve
1
Flange ball valve
2
Structure Type
Integral
1
Remote
2
Power Supply
AC220V
A
DC24V
B
3.6V Lithium Battery
E
Others
G
Ex-proof
Without Ex-proof
0
With Ex-proof
1
Protection
IP65
A
IP68
B

Installation

Installation environment selection
1. Stay away from devices with strong electromagnetic fields. Such as large motor, large transformer, large frequency conversion equipment.
2. The installation site should not have strong vibration, and the ambient temperature does not change much.
3. Convenient for installation and maintenance.


Selection of installation location

1. The flow direction mark on the sensor must be consistent with the flow direction of the measured medium in the pipeline.
2. The installation position must ensure that the measuring tube is always filled with the measured medium.
3. Select the place where the fluid flow pulse is small, that is, it should be far away from the water pump and local resistance parts (valves, elbows, etc.)
4. When measuring the two-phase fluid, choose the place which is not easy to cause phase separation.
5. Avoid installation in the area with negative pressure in the tube.
6. When the measured medium easily causes the electrode and the inner wall of the measuring tube to adhere to and scale, it is recommended that the flow rate in the measuring tube be no less than 2m/s. At this time, a tapered tube slightly smaller than the process tube can be used. In order to clean the electrode and measuring tube without interrupting the flow in the process tube, the sensor can be installed in parallel with a cleaning port.


Upstream straight pipe section requirements
The requirements of the sensor on the upstream straight pipe section are shown in the table. When the diameters of the upstream and downstream straight pipe sections are inconsistent with those of the electromagnetic cold water meter, the tapered pipe or the tapered pipe should be installed, and its conical Angle should be less than 15° (7° -8 ° is preferred) and then connected with the pipe.

less than 15° (7° -8 ° is preferred) and then connected with the pipe.

 Upstream resistance 
components

Note: L is straight pipe length
Straight pipe requirementsL=0D can be considered as a 
straight pipe section
L≥5DL≥10D

Note :(L is the length of straight pipe section, D is the nominal diameter of sensor)

Other Products in ' Electromagnetic Flow Meter' category

SEND YOUR INQUIRY

Exported to more than 150 countries around the globe, 10000 sets/month production capacity!

OUR GLOBAL PRESENCE

Nature of business – MANUFACTURER , EXPORTER